SOP 12.0 – Water Safety & Legionella Management

12.0 Water

Water Safety & Legionella Management Standard Operating Procedure (SOP) Version: V2 Date: October 2025 Purpose: Ensure safe water supply, prevent Legionella contamination, and maintain water system compliance across all Little Coffee Bean Co locations. Scope All fixed locations and mobile units (Tuk Tuks) serving food and beverages. Key Responsibilities Daily water system checks Weekly system flushing and maintenance Monthly temperature monitoring Quarterly professional inspections Annual risk assessments Water Safety Principles 1. Temperature Control Hot water: Maintain at 60°C or above Cold water: Keep below 20°C Check temperatures daily using calibrated thermometers Record all readings on the Water Temperature Log 2. System Flushing Flush all outlets daily (at least 30 seconds each) Includes taps, showers, and coffee machine lines Removes stagnant water and reduces bacterial growth Document flushing times on daily checklist 3. Legionella Prevention Risk assessment required annually (or when system changes) Professional water testing quarterly Maintain detailed records of all maintenance Report any suspected contamination immediately to management 4. Water Quality Checks Visual inspection: Water should be clear, no discoloration Odour check: No unusual smells Taste test (staff only): No unusual taste Report any concerns to duty manager 5. System Maintenance Clean aerators and screens monthly Check for leaks daily Inspect pipes for corrosion or damage Replace filters according to manufacturer guidance Document all maintenance activities Equipment Required Calibrated thermometer Water testing kit (quarterly use) Cleaning cloths and brushes Personal protective equipment (gloves) Maintenance log sheets Daily Procedures Opening Shift: Check water pressure at all outlets Flush all taps for 30 seconds Check coffee machine water lines Record water temperature (hot and cold) Visually inspect for leaks Throughout Shift: Monitor water flow and pressure Report any discoloration or odours immediately Ensure taps are fully closed after use Check for any new leaks Closing Shift: Flush all outlets again for 30 seconds Turn off water pump (mobile units) Check macerator power (fixed locations) Document any issues on incident form Report problems to manager Weekly Tasks Deep clean all aerators Inspect visible pipes for corrosion Test water temperature at multiple points Flush system thoroughly Review and sign maintenance log Monthly Tasks Professional cleaning of water lines Filter replacement (if applicable) Full system inspection Water quality testing Update maintenance records Quarterly Tasks Professional water testing by certified lab Legionella risk assessment review System pressure and flow testing Documentation review and audit Annual Tasks Full Legionella risk assessment Professional system inspection Equipment servicing and certification Staff training refresh Compliance documentation review Safety Notes Never drink untested water Always use protective equipment when handling system components Report all leaks immediately Do not attempt repairs beyond your training Contact professional engineer for major issues Legionella Guidance Summary Legionella is a bacterium that grows in warm water environments (20-45°C). It causes Legionnaires’ disease, a serious respiratory infection. Prevention requires: Maintaining hot water above 60°C Keeping cold water below 20°C Regular system flushing Professional testing and monitoring Proper maintenance records UK Compliance References Health and Safety at Work etc. Act 1974 Management of Health and Safety at Work Regulations 1999 Control of Legionella Bacteria in Water Systems (ACoP L8) HSE Legionnaires’ disease guidance

28/10/2025 / Comments Off on SOP 12.0 – Water Safety & Legionella Management
read more

11.7 – Electrical Troubleshooting SOP

11.0 Electrical

Electricity Issues Standard Operating Procedure (SOP) Troubleshooting – Washington Active Should you face an issue with the electricity the following steps should be taken: You should not attempt to work on any bit of equipment while it is still plugged in to the mains electricity supply. Where is the fuse board located at the Washington Store? “Fuse boxes are also known as circuit breakers, there are two located at the Washington store” “Check in the following order.” Check the fuse box inside the cafe area first. It is the white box with a red sticker located under the bench with the coffee machine. It is to the left of the upstand pipe to the left of the fridge and freezer. You might have to move the bins out of the way to get access. Once you find it lift the flap panel Check that the switches are in the correct position. At the Washington store they are all black switches. “Can you confirm the switches should all be in the up position?” “If the switches are not in the up position, push them up one at a time.” Review to see if this has resolved the issue: If one of the circuit switches won’t stay up: Now you need to be a detective, you need to work out which bits of equipment are not working due to the circuit fault, this will help identify the cause of the fault. Once you have found the appliances on the faulty circuit, switch off each of the individual plug sockets Now return to the fuse board and push up the black circuit breaker, if this stays on, it is time to start switching the individual plug sockets back on. One at a time switch the individual plug sockets back on, you must check the circuit breaker each time to see if it has tripped. If not, move to the next plug and repeat. Once you find the bit of equipment that is causing the circuit to isolate, unplug it and report it via the Service Agent and submit an incident report form. If the switches are all up but there is still no power you will need to check the sub fuse box in the cupboard where we store the excess pop. You will need to ask for the fuse board key from the centre’s duty manager. Once you find the single bit of equipment causing the fault: Spare fuses are kept on site. You should only change a plug fuse if you are confident that you know how to do it safely. ENSURE THERE IS NO ELECTRICITY GOING TO THE EQUIPMENT FIRST. If you are unable to identify the issue: Do not attempt to fix electrical equipment yourself. Report the issue to the duty manager who will then escalate the issue and contact the company electrician to attend the site. If the item is isolated to one bit of equipment: If the item is isolated to one bit of equipment then it is likely to be the fuse in the plug. Spare fuses are kept on site. You should only change a plug fuse if you are confident that you know how to do it safely. ENSURE THERE IS NO ELECTRICITY GOING TO THE EQUIPMENT FIRST. If you are unable to identify the issue: Do not attempt to fix electrical equipment yourself. Report the issue to the duty manager who will then escalate the issue and contact the company electrician to attend the site. ALL ELECTRICAL ISSUES SHOULD BE NOTED ON THE DAILY CLOSING SHEET AND REPORTED VIA THE ONLINE INCIDENT REPORT FORM Electrical Troubleshooting SOP 04/03/2023 v1

27/10/2025 / Comments Off on 11.7 – Electrical Troubleshooting SOP
read more

11.6 Emergency Electrical Shutdown V2

11.0 Electrical

# 11.6 Emergency Electrical Shutdown V2 **Company:** Little Coffee Bean Co **Version:** V2 **Last Updated:** October 2025 **Review Date:** October 2026 — ## Purpose This SOP establishes critical procedures for safely shutting down electrical systems during emergencies including electrical fires, equipment malfunction, smoke, sparks, or other electrical hazards. These procedures protect staff safety, prevent equipment damage, and minimize business disruption. ## Scope This procedure applies to: – All Little Coffee Bean Co locations (fixed shops and mobile Tuk Tuks) – All staff members working with electrical equipment – Emergency situations involving electrical hazards – Planned emergency shutdown drills ## Equipment Required – Emergency shutdown switches (where installed) – Circuit breaker panel access – Fire extinguisher (Class C/electrical rated) – Personal protective equipment (insulated gloves if available) – Emergency contact list – Incident report forms — ## Emergency Shutdown Procedures ### 1. Immediate Response to Electrical Emergency **When to initiate emergency shutdown:** – Visible smoke or fire from electrical equipment – Sparks or arcing from outlets, switches, or equipment – Burning smell from electrical sources – Equipment overheating beyond normal operating temperature – Water contact with electrical systems – Exposed wiring or damaged electrical components – Repeated circuit breaker trips – Staff receiving electrical shocks **Immediate actions:** 1. **Alert all staff** – Shout “ELECTRICAL EMERGENCY” clearly 2. **Evacuate customers** from immediate danger area 3. **Do not touch** any electrical equipment with bare hands 4. **Do not use water** on electrical fires ### 2. Main Power Isolation **Step-by-step shutdown sequence:** **For Fixed Shop Locations:** 1. Locate the main electrical panel/fuse box 2. Identify the main circuit breaker (usually at top of panel) 3. Switch main breaker to OFF position (down) 4. Verify power loss by checking lights and equipment 5. If emergency shutdown switch is installed, use it first 6. Lock out the panel if possible to prevent accidental re-energization **For Mobile Tuk Tuk Units:** 1. Switch off the main power isolator switch 2. Disconnect from external power source if connected 3. Switch off LPG supply if applicable 4. Disconnect battery if safe to do so 5. Ensure all equipment has stopped operating ### 3. Equipment-Specific Shutdown **Coffee Machine:** – Allow machine to cool before touching – Do not open machine panels during emergency – Note any visible damage or burning **Grinder:** – Verify power disconnection – Check for overheating or burning smell – Clear any jammed beans if safe **POS System:** – Allow proper shutdown if time permits – Note transaction status for later recovery – Protect equipment from water/fire suppression **Refrigeration:** – Note shutdown time for food safety – Keep doors closed to maintain temperature – Plan for alternative cold storage if extended outage ### 4. Fire Response **If electrical fire is present:** **Small, contained fire (smaller than wastepaper basket):** 1. Use Class C fire extinguisher ONLY 2. Aim at base of fire 3. Sweep side to side 4. Do not use water or foam extinguishers **Large or spreading fire:** 1. Evacuate all staff and customers immediately 2. Call 999 (Fire Brigade) 3. Do not attempt to fight the fire 4. Close doors to contain fire if safe to do so 5. Evacuate to assembly point 6. Account for all staff ### 5. Post-Shutdown Safety Checks **After power is isolated:** 1. **Visual inspection** (from safe distance): – Check for smoke or smoldering – Look for damaged wiring or equipment – Identify source of problem if visible – Note any water damage 2. **Ventilation:** – Open windows and doors if safe – Use fans to clear smoke (battery-powered only) – Do not re-enter if heavy smoke present 3. **Secure the area:** – Cordon off affected area – Post warning signs – Prevent customer and staff access – Guard electrical panel to prevent unauthorized access ### 6. Emergency Contacts and Reporting **Immediate notifications (in order):** 1. **Emergency Services** (if required): – Fire: 999 – Ambulance: 999 (if injuries) 2. **Management Escalation:** – Store Manager (immediate) – Area Manager (within 15 minutes) – Operations Manager (within 30 minutes) – Company Director (for serious incidents) 3. **Utility Company:** – Report electrical hazards to local electricity provider – Request emergency inspection if required 4. **Insurance:** – Notify insurance provider within 24 hours – Document all damage with photos **Incident documentation:** – Complete Incident Report Form immediately – Record time of emergency – List all witnesses – Describe sequence of events – Note equipment involved – Document any injuries – Take photographs of damage – Preserve evidence for investigation ### 7. System Restart Procedures **DO NOT restart electrical systems until:** – Emergency has been fully resolved – Qualified electrician has inspected the system – All damaged equipment has been isolated – Written clearance from competent person received – Management has authorized restart **Restart sequence (when authorized):** 1. Ensure all equipment switches are OFF 2. Visual inspection of all equipment 3. Check for water or contamination 4. Restore main power at circuit breaker 5. Test each circuit individually 6. Power up equipment one at a time 7. Monitor for any abnormal operation 8. Complete restart checklist ### 8. Staff Communication During Emergency **Clear communication protocols:** – Use loud, clear voice commands – Designate one person to call emergency services – Assign roles (evacuation coordinator, first aider, etc.) – Keep customers calm and informed – Do not spread panic – Use established assembly point – Account for all persons **Customer communication:** – Apologize for disruption – Ensure customer safety first – Provide clear evacuation instructions – Do not discuss cause or blame – Refer media inquiries to management — ## Quality Checks – [ ] All staff trained on emergency shutdown procedures – [ ] Emergency shutdown switches clearly labeled and accessible – [ ] Circuit breaker panel location known to all staff – [ ] Fire extinguishers inspected and rated for electrical fires – [ ] Emergency contact list current and accessible – [ ] Incident report forms readily available – [ ] Evacuation routes clearly marked – [ ] Assembly point designated and communicated –

27/10/2025 / Comments Off on 11.6 Emergency Electrical Shutdown V2
read more

11.5 Fuse Box & Circuit Breaker Management V2

11.0 Electrical

# 11.5 Fuse Box & Circuit Breaker Management **Version:** V2 **Date:** October 2025 **Section:** 11 – Electrical — ## Purpose To establish procedures for managing fuse boxes and circuit breakers at Little Coffee Bean Co locations, ensuring electrical safety and proper equipment operation. — ## Scope This SOP applies to all staff, managers, and franchisees responsible for electrical safety and equipment management at fixed shop locations and mobile Tuk Tuk units. — ## Fuse Box Overview ### What is a Fuse Box/Circuit Breaker? A fuse box (or circuit breaker panel) is the central electrical distribution point for a location. It: – Controls power distribution to different circuits – Protects electrical systems from overload and short circuits – Allows isolation of circuits for safety and maintenance ### Types of Fuse Boxes **Modern Circuit Breaker Panels:** – Individual switches (breakers) for each circuit – Switches move to OFF when circuit is overloaded – Safer and easier to manage than older fuse boxes **Older Fuse Boxes:** – Use replaceable fuses instead of switches – Fuses blow when circuit is overloaded – Require replacement with correct amperage fuse — ## Location and Access ### Finding Your Fuse Box 1. Refer to **Local Electrical Operating Procedures** for exact location 2. Common locations: – Inside: Near main entrance, kitchen, utility room, or basement – Outside: On exterior wall or in external cabinet – Mobile units: Inside Tuk Tuk, typically near entrance or power supply ### Ensuring Safe Access 1. **Keep area clear:** – Remove boxes, equipment, or obstructions – Ensure 1 meter clearance in front of fuse box – Keep area dry and free from moisture 2. **Labeling:** – Ensure fuse box is clearly labeled – Keep circuit labels visible and legible – Update labels if circuits change 3. **Security:** – Lock fuse box if required by local procedures – Restrict access to trained staff only – Keep key in secure location — ## Understanding Your Circuits ### Circuit Identification 1. **Locate circuit map/diagram:** – Usually inside fuse box door – Shows which circuits control which areas/equipment – Update if equipment changes 2. **Common circuits in coffee shops:** – **Lighting circuits:** Lights throughout location – **Power circuits:** General outlets and equipment – **Kitchen circuits:** Coffee machines, grills, fryers – **Refrigeration circuits:** Fridges, freezers, display units – **Water heater circuit:** Hot water systems – **Emergency circuits:** Emergency lighting, alarms 3. **Circuit capacity:** – Each circuit has a rated amperage (e.g., 10A, 16A, 20A) – Do not exceed rated capacity – Overloading causes breaker to trip ### Documenting Circuits Maintain **Local Electrical Operating Procedures** document showing: – Circuit number and location – What equipment/area each circuit controls – Amperage rating – Any special requirements – Emergency contact for electrician — ## Daily Fuse Box Checks ### Opening Checks 1. **Visual inspection (2 minutes):** – Check all breakers are in normal position (ON) – Look for any tripped breakers (middle or OFF position) – Check for signs of burning, damage, or moisture – Ensure area is clear and accessible 2. **If breaker is tripped:** – Note which circuit is affected – Check if equipment on that circuit is faulty – Do not reset immediately – Report to manager ### Closing Checks 1. **Final inspection (2 minutes):** – Verify all breakers are in normal ON position – Check for any new issues – Ensure area is secure and clear — ## Resetting a Tripped Circuit Breaker ### When to Reset A circuit breaker trips when: – Circuit is overloaded (too many devices) – Equipment has a fault – Short circuit has occurred ### Safe Reset Procedure **Only reset if:** – No signs of damage or burning – No water or moisture present – You have been trained to do so – Manager has approved **To reset:** 1. **Identify the tripped breaker:** – Look for switch in middle or OFF position – Note circuit number from label 2. **Investigate the cause:** – Check if equipment on that circuit is faulty – Look for damaged cables or plugs – Unplug any suspicious equipment 3. **Reset the breaker:** – Switch breaker firmly to OFF position – Wait 10 seconds – Switch firmly back to ON position 4. **Monitor:** – Watch breaker for 2 minutes – If breaker holds (stays ON): Circuit is safe – If breaker trips again: Do not reset again ### If Breaker Trips Immediately After Reset **Action:** 1. Do not reset again 2. Report to manager immediately 3. Contact qualified electrician 4. Do not use equipment on that circuit 5. Follow Troubleshooting Escalation Protocol (Section 1.3) — ## Isolating Circuits ### When to Isolate a Circuit Isolate a circuit (turn breaker OFF) when: – Equipment on that circuit is faulty or damaged – Maintenance or repair work is needed – Power needs to be cut for safety reasons – Following instructions from qualified electrician ### Safe Isolation Procedure 1. **Inform relevant staff:** – Tell staff that circuit will be isolated – Identify which equipment will be without power 2. **Locate the breaker:** – Find correct breaker using circuit map – Double-check circuit number and equipment 3. **Switch breaker OFF:** – Switch firmly to OFF position – Verify equipment loses power 4. **Label the breaker:** – Place “DO NOT SWITCH ON” label if available – Inform all staff not to switch on 5. **Document:** – Record date, time, and reason for isolation – Note which circuit was isolated – Update maintenance log 6. **Re-enable when safe:** – Only after repair/maintenance is complete – After qualified electrician approval – Switch breaker firmly back to ON – Verify equipment has power – Remove “DO NOT SWITCH ON” label — ## Overloaded Circuits ### Signs of Overloading – Breaker trips frequently – Burning smell near fuse box – Lights dimming when equipment switches on – Equipment not working properly – Hot cables or plugs ### Preventing Overload 1. **Know circuit capacity:** – Refer to circuit map for amperage rating – Calculate total load of equipment on circuit 2. **Distribute load:** – Do not

27/10/2025 / Comments Off on 11.5 Fuse Box & Circuit Breaker Management V2
read more

11.4 Power Failure Procedures V2

11.0 Electrical

# 11.4 Power Failure Procedures **Version:** V2 **Date:** October 2025 **Section:** 11 – Electrical — ## Purpose To establish clear procedures for staff to follow during power failures or electrical outages, ensuring safety, customer communication, and business continuity at Little Coffee Bean Co locations. — ## Scope This SOP applies to all staff at fixed shop locations and mobile Tuk Tuk units during power failures or electrical outages. — ## Immediate Actions (First 5 minutes) ### Step 1: Assess the Situation 1. Determine if power failure is: – **Location-wide** (entire shop/Tuk Tuk without power) – **Partial** (some equipment without power) – **Isolated** (single circuit or equipment affected) 2. Check: – Are other nearby businesses affected? (indicates wider area outage) – Is the fuse box/circuit breaker accessible? – What time is it? (affects customer impact) ### Step 2: Ensure Safety 1. **Turn off all equipment** to prevent damage when power returns 2. **Prevent hazards:** – Keep customers away from kitchen areas – Ensure emergency lighting is functioning – Check for any burning smells or electrical hazards – Do not touch any electrical equipment 3. **If fire or electrical hazard suspected:** – Evacuate immediately – Call emergency services (999) – Do not attempt to investigate ### Step 3: Inform Manager/Franchisee 1. Contact manager or franchisee immediately 2. Report: – Time of power failure – Extent of outage (location-wide or partial) – Any hazards or concerns – Whether other businesses affected — ## Customer Communication ### Using Customer Scripts Refer to the **Customer Power Failure Scripts** (available in company documentation) for consistent, professional communication with customers. Scripts include: – Greeting and apology for inconvenience – Clear explanation of the situation – Estimated time to resolution (if known) – Offer of alternatives (if available) – Contact information for updates ### Verbal Communication If scripts are not available, use this approach: 1. **Acknowledge the issue:** – “I’m sorry, we’re experiencing a power outage at the moment.” 2. **Explain impact:** – “We’re unable to serve hot drinks/take card payments/operate our equipment.” 3. **Provide timeframe:** – “We’re working to restore power. We’ll update you shortly.” 4. **Offer alternatives:** – “We can offer cold drinks/refunds/alternative service if available.” 5. **Thank them:** – “Thank you for your patience and understanding.” ### Signage 1. Place clear signage at entrance: – “Temporary power outage – We apologize for the inconvenience” – “We’re working to restore service” – Estimated time to resolution (if known) 2. Update social media: – Post on Facebook, Instagram, TikTok, X – Brief explanation and expected resolution time – Thank customers for patience — ## Checking the Fuse Box/Circuit Breaker ### Step 1: Locate Fuse Box (per local procedures) 1. Refer to **Local Electrical Operating Procedures** for fuse box location 2. Ensure area is clear and safe to access ### Step 2: Visual Inspection 1. Look for: – Tripped circuit breakers (switch in middle or OFF position) – Signs of burning or damage – Water or moisture – Any obvious hazards 2. **If hazards found:** – Do not touch fuse box – Report to manager – Contact qualified electrician – Proceed to “Calling for Help” section ### Step 3: Reset Circuit Breaker (if safe) 1. **Only if:** – No signs of damage or burning – No water or moisture present – You have been trained to do so 2. **To reset:** – Switch breaker firmly to OFF position – Wait 10 seconds – Switch firmly back to ON position 3. **If breaker trips again immediately:** – Do not reset again – Contact qualified electrician – Proceed to “Calling for Help” section — ## If Power Does Not Return ### Step 1: Check with Neighbors/Utility Company 1. Ask nearby businesses if they have power 2. If area-wide outage: – Contact local utility company (typically UK Power Networks, Scottish Power, etc.) – Report outage – Get estimated restoration time 3. If outage is only at your location: – Proceed to “Calling for Help” section ### Step 2: Calling for Help 1. **Contact qualified electrician:** – Use contact details from Local Electrical Operating Procedures – Describe the situation clearly – Provide location address and access details 2. **Document the incident:** – Record time of outage – Time of restoration – Any damage or issues – Actions taken 3. **Contact manager/franchisee:** – Inform of electrician contact and ETA – Discuss business continuity options — ## During Extended Power Outage ### Protecting Equipment 1. **Leave all equipment switched OFF** – Do not attempt to use equipment on backup power unless trained – Wait for power to fully stabilize before switching on 2. **Refrigeration:** – Keep fridge/freezer doors closed – Minimize opening to preserve temperature – If outage extends beyond 4 hours, follow food safety procedures (Section 2) 3. **POS System:** – Do not force shut down if powered off – Wait for controlled shutdown when power returns ### Business Continuity 1. **If outage is short (under 30 minutes):** – Offer cold drinks and packaged items – Take manual payment details (card details securely) – Apologize for inconvenience 2. **If outage is extended (over 30 minutes):** – Consider closing location – Offer refunds for orders – Post updates on social media – Contact manager for guidance 3. **Mobile Tuk Tuk units:** – If power loss affects refrigeration/equipment: – Stop serving immediately – Secure location – Contact manager for guidance — ## When Power Returns ### Step 1: Safety Check 1. **Wait 2 minutes** before switching on equipment 2. **Check for:** – Burning smells – Visible damage – Unusual sounds – Smoke or sparks 3. **If hazards present:** – Do not switch on equipment – Contact qualified electrician – Evacuate if necessary ### Step 2: Equipment Restart 1. **Restart in this order:** – Lighting first – Refrigeration units – POS system – Coffee machines and other equipment 2. **Monitor equipment:** – Listen for unusual sounds – Watch for error messages – Check all systems functioning normally 3. **If equipment not functioning:** – Do not force restart – Contact manager – Contact qualified electrician if

27/10/2025 / Comments Off on 11.4 Power Failure Procedures V2
read more

11.3 PAT Testing V2

11.0 Electrical

# 11.3 PAT Testing **Version:** V2 **Date:** October 2025 **Section:** 11 – Electrical — ## Purpose To ensure all portable electrical equipment at Little Coffee Bean Co locations is safe and compliant with UK electrical safety regulations through regular Portable Appliance Testing (PAT). — ## Scope This SOP applies to all portable electrical equipment at fixed shop locations and mobile Tuk Tuk units. This includes but is not limited to: – Coffee machines (portable units) – Kettles and hot water dispensers – Toasters – Microwaves – Blenders – POS terminals – Chargers and adapters – Extension leads and power strips – Any other portable electrical equipment — ## PAT Testing Overview ### What is PAT Testing? Portable Appliance Testing (PAT) is the process of checking electrical equipment to ensure it is safe to use. Testing includes visual inspection and electrical testing in accordance with UK regulations (BS 7671 and HSE guidance). ### Testing Standards – Equipment is tested in line with manufacturers’ specifications and latest HSE guidance – Testing frequency varies based on location risk assessment and lease requirements – Equipment purchased new is exempt from PAT testing for the first 12 months — ## Testing Schedule ### Initial Assessment 1. Franchisee or manager conducts risk assessment for their location 2. Assessment considers: – Type of equipment – Frequency of use – Environment (wet/dry, high-risk areas) – Manufacturer recommendations – Lease requirements ### Testing Frequency Testing frequency is determined by: – **High-risk environments** (wet areas, kitchens): Annual testing – **Standard environments** (offices, retail): 24-month testing – **Low-risk environments**: 36-48 month testing – **New equipment:** Exempt for first 12 months **Note:** Specific testing schedules vary per location and are subject to individual assessment by the Health and Safety Team and requirements of the lease. — ## PAT Testing Process ### Step 1: Schedule Testing (ongoing) 1. Franchisee or manager schedules PAT testing with approved electrical contractor 2. Provide contractor with: – List of all portable equipment to be tested – Location address and access details – Any specific requirements or concerns ### Step 2: Pre-Testing Preparation (before testing date) 1. Ensure all equipment is accessible to the tester 2. Compile list of all portable electrical equipment 3. Gather any manufacturer documentation or previous test records 4. Inform staff that testing will take place ### Step 3: Visual Inspection (conducted by tester) The tester will visually inspect each item for: – Damage to cables or plugs – Loose connections – Signs of burning or discoloration – Appropriate grounding/earthing – Correct fuse ratings – Condition of equipment casing **Action if visual inspection fails:** Equipment is marked as failed and must not be used. ### Step 4: Electrical Testing (conducted by tester) The tester will perform electrical tests including: – Earth continuity testing – Insulation resistance testing – Leakage current testing – RCD (Residual Current Device) testing where applicable ### Step 5: Labeling (conducted by tester) 1. Equipment that passes testing receives a PAT test label showing: – Test date – Next test due date – Tester identification – Test result (PASS) 2. Equipment that fails testing receives a FAILED label and must not be used ### Step 6: Documentation and Records 1. Tester provides test report documenting: – All equipment tested – Test results (pass/fail) – Any failed equipment – Recommendations 2. Manager/franchisee must: – File test report securely – Update equipment inventory – Remove failed equipment from service – Schedule replacement or repair of failed items — ## Failed Equipment ### Action for Failed Equipment 1. **Immediately remove from service** – Do not use failed equipment 2. **Label clearly** – Ensure FAILED label is visible 3. **Isolate** – Store in designated area away from staff access 4. **Report** – Inform manager and document in maintenance log 5. **Replace or repair** – Arrange replacement or repair by qualified electrician 6. **Re-test** – If repaired, equipment must be re-tested before use — ## Record Keeping Maintain records of: – All PAT testing dates and results – Equipment serial numbers and descriptions – Tester details and company – Next test due dates – Any failed equipment and actions taken – Replacement or repair records **Storage:** Records must be kept securely and be accessible for inspection by Health and Safety Team or regulatory authorities. — ## Responsibilities ### Franchisees – Conduct initial risk assessment for their location – Schedule PAT testing according to assessment – Maintain testing records – Ensure failed equipment is removed from service – Budget for testing costs ### Managers – Assist with equipment inventory – Coordinate testing schedules – Ensure staff are aware of testing – Monitor equipment condition between tests – Report any electrical concerns ### All Staff – Report any damaged or faulty equipment immediately – Do not use equipment with failed PAT labels – Treat electrical equipment with care — ## Escalation If equipment fails PAT testing or shows signs of electrical hazard: 1. Remove from service immediately 2. Report to manager 3. Follow company Troubleshooting Escalation Protocol (Section 1.3) 4. Do not attempt to repair — ## Safety Notes – **Never** use equipment with a failed PAT label – **Never** ignore warning signs (burning smells, sparks, unusual sounds) – **Never** attempt to repair electrical equipment yourself – **Always** report damaged equipment immediately — ## References – Health and Safety Executive (HSE) Electrical Safety Guidance – BS 7671 Requirements for Electrical Installations – Maintaining Portable Electric Equipment in Low-Risk Environments (HSE guidance) – Company Troubleshooting Escalation Protocol (Section 1.3) – Local Electrical Operating Procedures (location-specific)

27/10/2025 / Comments Off on 11.3 PAT Testing V2
read more

11.2 Daily Electrical Safety Checks V2

11.0 Electrical

# 11.2 Daily Electrical Safety Checks **Version:** V2 **Date:** October 2025 **Section:** 11 – Electrical — ## Purpose To ensure all electrical equipment and installations at Little Coffee Bean Co locations are safe for use and to identify potential electrical hazards before they cause injury or damage. — ## Scope This SOP applies to all staff responsible for opening and closing procedures at fixed shop locations and mobile Tuk Tuk units. — ## Equipment Required – Checklist (printed or digital) – Torch/flashlight – Notebook for recording issues – Contact details for manager/electrician — ## Daily Opening Electrical Safety Checks ### Step 1: Visual Inspection of Plugs and Cables (5 minutes) 1. Walk around the location and visually inspect all visible electrical cables and plugs 2. Look for: – Damaged or frayed cables – Loose or damaged plugs – Cables running under carpets or mats – Cables in wet areas without proper protection – Overloaded power outlets (too many plugs in one socket) – Signs of burning or discoloration around plugs/sockets 3. **Action if issue found:** Do not use the equipment. Report immediately to manager. ### Step 2: Check Power Supply to Key Equipment (5 minutes) 1. Verify power is supplied to: – Coffee machines – Refrigeration units – POS systems – Lighting systems – Hot water systems – Any other critical equipment per local procedures 2. **Action if equipment not powered:** Check circuit breaker (Section 11.5) or contact manager. ### Step 3: Inspect Light Fittings (3 minutes) 1. Check all light fittings for: – Broken or missing bulbs – Loose fittings – Water damage or moisture – Flickering lights 2. **Action if issue found:** Report to manager. Do not attempt to repair. ### Step 4: Check Fuse Box/Circuit Breaker Area (2 minutes) 1. Visually inspect fuse box/circuit breaker location (per local procedures) 2. Check for: – Loose or tripped circuit breakers – Signs of burning or damage – Obstructions blocking access – Water or moisture near fuse box 3. **Action if issue found:** Report immediately to manager. ### Step 5: Test Emergency Lighting (if applicable) (2 minutes) 1. Check emergency exit lights are illuminated 2. Verify they are functioning correctly 3. **Action if not working:** Report to manager immediately — ## Daily Closing Electrical Safety Checks ### Step 1: Equipment Shutdown (5 minutes) 1. Switch off all non-essential equipment: – Coffee machines – Grills and cooking equipment – Slush machines – Display fridges (if permitted by local procedures) 2. Leave on only: – Security lighting – Refrigeration units (as per local procedures) – Alarm systems ### Step 2: Final Cable and Plug Inspection (3 minutes) 1. Perform final visual inspection of cables and plugs 2. Ensure no equipment is left plugged in unnecessarily 3. Check for any new damage or hazards ### Step 3: Fuse Box/Circuit Breaker Final Check (2 minutes) 1. Verify all circuit breakers are in normal position 2. Check for any tripped breakers 3. **Action if breaker tripped:** Do not reset. Report to manager. ### Step 4: Secure Fuse Box Area (1 minute) 1. Ensure fuse box area is clear and accessible 2. Lock fuse box if required by local procedures — ## Recording and Reporting 1. Complete daily electrical safety checklist 2. Note any issues or concerns 3. Report immediately to manager if: – Any damage or hazards identified – Equipment not functioning – Unusual sounds or smells from electrical equipment – Flickering lights or power fluctuations — ## Escalation If any electrical hazard is identified: 1. Stop using the affected equipment immediately 2. Report to immediate manager 3. Follow company Troubleshooting Escalation Protocol (Section 1.3) 4. Do not attempt to repair electrical equipment — ## Safety Notes – **Never** touch electrical equipment with wet hands – **Never** attempt to repair electrical equipment – **Never** ignore warning signs (burning smells, sparks, unusual sounds) – **Never** overload power outlets – **Never** use damaged cables or plugs — ## References – Health and Safety Executive (HSE) Electrical Safety Guidance – BS 7671 Requirements for Electrical Installations – Company Troubleshooting Escalation Protocol (Section 1.3) – Local Electrical Operating Procedures (location-specific)

27/10/2025 / Comments Off on 11.2 Daily Electrical Safety Checks V2
read more

11.1 Electrical Safety Overview V2

11.0 Electrical

# 11.1 Electrical Safety Overview **Version:** V2 **Date:** October 2025 **Last Updated:** 27 October 2025 — ## Purpose To establish a framework for electrical safety across all Little Coffee Bean Co locations (mobile Tuk Tuks and fixed shops) in compliance with UK electrical safety regulations, Health and Safety Executive (HSE) guidance, and company policy. — ## Scope This SOP applies to all staff, managers, and franchisees responsible for electrical equipment operation, maintenance, and safety at all Little Coffee Bean Co locations. — ## Regulatory Framework – **BS 7671:2018** – Wiring Regulations (UK electrical installation standard) – **Health and Safety at Work etc. Act 1974** – **Electricity at Work Regulations 1989** – **HSE Guidance on Electrical Safety in the Workplace** – **UK Food Standards Agency (FSA) Guidelines** for commercial kitchens — ## Key Principles ### 1. Prevention of Electrical Hazards All electrical equipment must be: – Properly installed by qualified electricians – Regularly inspected and tested – Maintained in safe working condition – Immediately removed from service if damaged or faulty ### 2. Competence Only qualified electricians may: – Install or modify electrical systems – Perform PAT testing – Repair electrical equipment – Conduct electrical safety inspections Staff may operate equipment but must report faults immediately. ### 3. Risk Assessment Each location has an individual electrical risk assessment that identifies: – Hazards specific to the site – Equipment in use – Testing schedules – Emergency procedures – Fuse box and circuit breaker locations **Note:** Local operating procedures for your specific location will detail the exact locations of fuse boxes, circuit breakers, and emergency shutdown points. ### 4. Emergency Procedures All staff must know: – Location of main electrical switch/isolator – How to safely shut down power in an emergency – Who to contact in case of electrical fault or hazard – Escalation procedures (see Section 1.3 – Troubleshooting Escalation Protocol) — ## Electrical Equipment Categories ### High-Risk Equipment – Coffee machines (Frachino dual-fuel) – Fryers – Grills (Panini, flat) – Pizza ovens – Hot holding equipment – Refrigeration units ### Standard Equipment – Tills/POS systems – Milk frothers – Blenders – Toasters – Kettles ### Low-Risk Equipment – Lights – Fans – Chargers – Small hand tools — ## Common Electrical Hazards | Hazard | Risk | Control | |——–|——|———| | Damaged cables/plugs | Electric shock, fire | Daily visual checks, immediate removal | | Wet environments | Electric shock | Proper drainage, RCD protection | | Overloaded circuits | Fire, equipment damage | Load assessment, separate circuits | | Faulty equipment | Electric shock, injury | PAT testing, immediate repair/removal | | Poor maintenance | Equipment failure, safety risk | Regular inspection, preventive maintenance | | Untrained staff | Misuse, injury | Comprehensive training, supervision | — ## Staff Responsibilities **All Staff:** – Conduct daily visual checks of equipment (Section 11.2) – Report electrical faults immediately to manager – Do not attempt to repair electrical equipment – Follow emergency procedures (Section 11.6) **Managers:** – Ensure PAT testing is scheduled (Section 11.3) – Maintain electrical safety records – Coordinate with qualified electricians for repairs – Escalate urgent electrical hazards (Section 1.3) **Franchisees:** – Ensure compliance with all electrical safety procedures – Arrange PAT testing per company schedule – Maintain local operating procedures for fuse box/circuit breaker locations – Report all electrical incidents — ## Local Operating Procedures **Each location will have a Local Operating Procedure document that includes:** – Exact location of main electrical switch/isolator – Fuse box location and layout – Circuit breaker identification and purpose – Emergency shutdown procedures specific to that site – Contact details for qualified electrician – Equipment inventory and testing schedule **Franchisees and managers must ensure this document is:** – Displayed prominently near the main electrical switch – Accessible to all staff – Updated whenever electrical changes are made – Reviewed during induction training — ## Related Sections – **Section 1.3** – Troubleshooting Escalation Protocol – **Section 14.2** – Risk Assessment – **Section 14.7** – Gas Safety (for dual-fuel equipment) – **Section 8** – Cleaning and Maintenance (equipment care) — ## References – Health and Safety Executive (HSE) – Electrical Safety in the Workplace – BS 7671:2018 – Requirements for Electrical Installations – Electricity at Work Regulations 1989 – UK Food Standards Agency – Commercial Kitchen Safety — ## Sign-Off **Created by:** Little Coffee Bean Co Operations Team **Approved by:** Company Director **Next Review Date:** October 2026

27/10/2025 / Comments Off on 11.1 Electrical Safety Overview V2
read more

10.2 Cleaning the Slush Machine

10.0 Slush Mix

# 10.2 Cleaning the Slush Machine **Version:** V2 **Last Updated:** October 2025 **Document Type:** Standard Operating Procedure (SOP) — ## Purpose To establish consistent cleaning and maintenance procedures for slush machines, ensuring food safety compliance, hygiene standards, and optimal machine performance across all Little Coffee Bean Co locations. — ## Scope This procedure applies to all staff responsible for operating and maintaining slush machines at mobile Tuk Tuk units and fixed shop locations. Cleaning must be performed daily, weekly, and during deep maintenance cycles. — ## Equipment Required ### Daily Cleaning – Warm water (40–50°C) – Food-safe cleaning solution (approved by FSA) – Soft-bristled brushes (non-abrasive) – Clean lint-free cloths or paper towels – Disposable gloves (food-grade) – Sanitiser spray (approved for food contact surfaces) – Bucket or sink ### Weekly & Deep Cleaning – All items from Daily Cleaning, plus: – Descaling solution (commercial food-grade) – Pipe cleaning brush or flexible brush – Gasket removal tool (if applicable) – Replacement seals/gaskets (if worn) – Distilled water (for rinsing) — ## Daily Cleaning Procedure ### Step 1: Drain Remaining Slush Mix 1. Turn off slush machine at end of service 2. Allow mixture to cool to room temperature (approximately 30 minutes) 3. Open drain valve at base of machine 4. Place bucket underneath to catch remaining slush mix 5. Allow complete drainage (minimum 5 minutes) 6. Close drain valve securely ### Step 2: Rinse Reservoir 1. Remove any large debris from reservoir opening 2. Fill reservoir with warm water (40–50°C) 3. Turn machine on for 30 seconds to circulate water through internal pipes 4. Turn machine off 5. Open drain valve and allow water to drain completely 6. Repeat rinse cycle 2–3 times until water runs clear ### Step 3: Clean Dispensing Nozzle 1. Remove dispensing nozzle (if removable) according to equipment manual 2. Soak nozzle in warm water with food-safe cleaning solution for 5 minutes 3. Use soft-bristled brush to gently scrub interior and exterior 4. Rinse thoroughly under warm running water 5. Dry with lint-free cloth 6. Reattach nozzle securely ### Step 4: Wipe External Surfaces 1. Dampen soft cloth with warm water and cleaning solution 2. Wipe all external surfaces including: – Machine body – Control panel – Drain valve area – Base and feet 3. Pay special attention to areas where syrup residue may accumulate 4. Dry all surfaces with clean cloth 5. Sanitise external surfaces with approved sanitiser spray ### Step 5: Final Inspection 1. Check for any remaining syrup residue or sticky spots 2. Inspect drain valve for leaks or blockages 3. Verify nozzle is securely attached 4. Check power cord for damage 5. Document cleaning completion on daily log — ## Weekly Deep Cleaning Procedure ### Step 1: Perform Daily Cleaning (Full Cycle) 1. Complete all steps from Daily Cleaning Procedure above 2. Allow extra time for thorough drying between steps ### Step 2: Descale Internal Pipes 1. Prepare descaling solution according to manufacturer instructions 2. Fill reservoir with descaling solution 3. Turn machine on and allow solution to circulate for 10 minutes 4. Turn machine off and let solution sit for 15–20 minutes 5. Turn machine back on for 5 minutes to flush descaling solution 6. Turn off machine ### Step 3: Flush with Distilled Water 1. Empty reservoir completely 2. Fill reservoir with distilled water 3. Turn machine on and circulate for 2 minutes 4. Turn off and drain completely 5. Repeat flush cycle 3 times to remove all descaling solution residue 6. Final drain should be clear with no chemical smell ### Step 4: Clean Internal Reservoir 1. If accessible, remove reservoir according to equipment manual 2. Use pipe cleaning brush to scrub interior walls 3. Pay attention to corners and seams where residue accumulates 4. Rinse thoroughly with warm water 5. Dry completely before reinstalling 6. Reattach reservoir securely ### Step 5: Inspect Seals and Gaskets 1. Visually inspect all rubber seals and gaskets 2. Check for cracks, hardening, or discolouration 3. Look for signs of leaking or deterioration 4. If seals appear worn or damaged, note for replacement 5. Clean seals with damp cloth and dry thoroughly 6. Do not use abrasive materials on seals ### Step 6: Document Deep Cleaning 1. Record date and time of deep cleaning 2. Note any issues or damage observed 3. List any replacement parts needed 4. Sign off on completion — ## Monthly Maintenance Check ### Step 1: Operational Test 1. Prepare a small batch of slush mix (500ml syrup + 2.5–3.5 litres water, depending on ratio) 2. Pour into reservoir 3. Turn on machine and allow full freezing cycle (15–20 minutes) 4. Check consistency and texture 5. Verify temperature reaches 4–8°C 6. Test dispensing nozzle for smooth operation 7. Drain machine completely after test ### Step 2: Visual Inspection 1. Check all visible components for wear or damage 2. Inspect power cord for cuts or fraying 3. Verify all bolts and fasteners are tight 4. Check drain valve for proper sealing 5. Look for any signs of leaking or water damage 6. Inspect control panel buttons for sticking ### Step 3: Performance Documentation 1. Record machine performance notes 2. Document any issues requiring attention 3. Note if professional servicing is needed 4. Schedule repairs if necessary with equipment supplier — ## Seasonal Deep Maintenance (Quarterly) ### Step 1: Complete Disassembly (If Qualified) 1. **Note:** Only perform if trained and authorised 2. Turn off and unplug machine 3. Allow 1 hour cooling time 4. Remove all removable parts according to equipment manual 5. Inspect each component for wear ### Step 2: Component Cleaning 1. Soak removable parts in descaling solution for 30 minutes 2. Use soft brushes to clean all surfaces 3. Rinse thoroughly with distilled water 4. Dry completely before reassembly 5. Replace any worn gaskets or seals ### Step 3: Reassembly 1. Follow equipment manual instructions carefully 2. Ensure all components are dry before reassembly 3. Tighten all fasteners securely but do not over-tighten 4. Verify all seals

27/10/2025 / Comments Off on 10.2 Cleaning the Slush Machine
read more

10.1 Slush Mix Calculations

10.0 Slush Mix

# 10.1 Slush Mix Calculations **Version:** V2 **Last Updated:** October 2025 **Document Type:** Standard Operating Procedure (SOP) — ## Purpose To ensure consistent slush drink quality, correct syrup-to-water ratios, and accurate batch calculations across all Little Coffee Bean Co locations. — ## Scope This procedure applies to all staff responsible for preparing and mixing slush batches at mobile Tuk Tuk units and fixed shop locations. — ## Equipment Required – Measuring jug (calibrated, minimum 5-litre capacity) – Slush syrup concentrate – Filtered or bottled water – Stirring rod or paddle – Thermometer (0–50°C range) – Funnel – Clean cloth or paper towels – Slush machine reservoir — ## Slush Mix Ratios Little Coffee Bean Co offers three standard mixing ratios to suit different flavour intensities and customer preferences. All ratios use **syrup concentrate to water** proportions. ### Ratio 1: 5:1 (Standard Sweetness) **Best for:** Regular customers, standard flavour intensity, balanced taste | Volume | Syrup Concentrate | Water | Total Batch | |——–|——————-|——-|————-| | Small | 1 litre | 5 litres | 6 litres | | Medium | 2 litres | 10 litres | 12 litres | | Large | 3 litres | 15 litres | 18 litres | | Extra Large | 5 litres | 25 litres | 30 litres | **Calculation:** Water volume = Syrup volume × 5 ### Ratio 2: 6:1 (Lighter Sweetness) **Best for:** Health-conscious customers, extended serving periods, subtle flavour | Volume | Syrup Concentrate | Water | Total Batch | |——–|——————-|——-|————-| | Small | 1 litre | 6 litres | 7 litres | | Medium | 2 litres | 12 litres | 14 litres | | Large | 3 litres | 18 litres | 21 litres | | Extra Large | 5 litres | 30 litres | 35 litres | **Calculation:** Water volume = Syrup volume × 6 ### Ratio 3: 7:1 (Light Sweetness) **Best for:** Sugar-conscious customers, premium dilution, extended shelf life | Volume | Syrup Concentrate | Water | Total Batch | |——–|——————-|——-|————-| | Small | 1 litre | 7 litres | 8 litres | | Medium | 2 litres | 14 litres | 16 litres | | Large | 3 litres | 21 litres | 24 litres | | Extra Large | 5 litres | 35 litres | 40 litres | **Calculation:** Water volume = Syrup volume × 7 — ## Step-by-Step Mixing Procedure ### Step 1: Select Ratio 1. Determine which ratio to use based on customer demand and preference 2. Confirm ratio selection with store manager if unsure 3. Record ratio used on batch log (see Quality Control section) ### Step 2: Measure Syrup Concentrate 1. Pour syrup concentrate into measuring jug 2. Fill to the marked line for your chosen volume 3. Check measurement at eye level to ensure accuracy 4. Do not overfill—excess syrup affects flavour balance ### Step 3: Measure Water 1. Add water to a separate measuring jug 2. Calculate water volume using the ratio formula: – **5:1 ratio:** Water = Syrup × 5 – **6:1 ratio:** Water = Syrup × 6 – **7:1 ratio:** Water = Syrup × 7 3. Measure water at eye level for accuracy 4. Use filtered or bottled water only (tap water may contain chlorine affecting taste) ### Step 4: Combine Ingredients 1. Pour syrup concentrate into the slush machine reservoir 2. Slowly add measured water while stirring continuously 3. Stir for minimum 2 minutes to ensure complete mixing 4. Check for any undissolved syrup particles at bottom of reservoir 5. If particles remain, continue stirring until fully dissolved ### Step 5: Check Temperature and Consistency 1. Allow mixture to cool to 4–8°C (refrigeration/freezing cycle) 2. Use thermometer to verify temperature before service 3. Mixture should be smooth with no visible particles 4. Consistency should be pourable but with slight viscosity ### Step 6: Activate Slush Machine 1. Ensure mixture is at correct temperature before switching on 2. Turn on slush machine according to equipment manual 3. Allow 15–20 minutes for initial freezing cycle 4. Check consistency after first cycle—should be partially frozen, slushy texture — ## Batch Calculations Reference ### Quick Reference: Common Batch Sizes **For 5:1 Ratio:** – 500ml syrup → 2.5 litres water = 3 litres total – 750ml syrup → 3.75 litres water = 4.5 litres total – 1 litre syrup → 5 litres water = 6 litres total **For 6:1 Ratio:** – 500ml syrup → 3 litres water = 3.5 litres total – 750ml syrup → 4.5 litres water = 5.25 litres total – 1 litre syrup → 6 litres water = 7 litres total **For 7:1 Ratio:** – 500ml syrup → 3.5 litres water = 4 litres total – 750ml syrup → 5.25 litres water = 6 litres total – 1 litre syrup → 7 litres water = 8 litres total — ## Quality Control Standards ### Visual Checks – Mixture is uniform colour (no streaking or separation) – No visible syrup particles or residue – Colour matches expected shade for chosen flavour – No cloudiness or discolouration ### Taste Profile – Flavour intensity matches selected ratio – No overly sweet or watered-down taste – Smooth consistency when served – No grittiness or texture issues ### Temperature – Mixture reaches 4–8°C before service – Slush consistency achieved after freezing cycle – Ice crystals form evenly throughout ### Documentation – Batch ratio recorded on batch log – Date and time of preparation noted – Staff member name recorded – Any deviations or issues documented — ## Troubleshooting | Issue | Cause | Solution | |——-|——-|———-| | Too sweet | Ratio too concentrated (5:1 used instead of 6:1/7:1) | Dilute with additional water; recalculate ratio | | Too watered down | Ratio too dilute (7:1 used instead of 5:1/6:1) | Add more syrup concentrate; remix | | Mixture won’t freeze | Temperature too high | Check refrigeration; allow longer freezing time | | Particles visible | Incomplete mixing | Stir for additional 2–3 minutes | | Colour inconsistent | Uneven mixing | Remix thoroughly; check

27/10/2025 / Comments Off on 10.1 Slush Mix Calculations
read more